Skip to main content
Fisher & Paykel Product Help

Hanging Non-Water Dispensing Door Panels

IMPORTANT! Failure to follow these steps can lead to difficulties in door panel adjustment and cosmetic cap fitment.
  1. Hang all door panels onto M8 studs and align the side bracket forks onto the refrigerator door.
  • Ensure the forks are positioned around the body of the side screws (M5 x 10 pan head Phillips screw).
  • Ensure the gap between the top of the door panel and the top cabinetry is no greater than 7 mm. To reduce this gap, raise the product by turning all four adjustment nuts the same number of turns.

    IMPORTANT!

    Failure to follow these steps can lead to difficulties in door panel adjustment and cosmetic cap fitment.

Screen_Shot_2018-01-08_at_8.22.03_AM.png
  1. Lock top inner panel side screws to allow opening the doors without affecting adjustment. (Open the left door to lock the right screws and vice versa).
fix15.png
  1. All door panels have full axis adjustment to ensure they are flush with adjacent walls. To adjust the height of each panel turn clockwise to raise stud or counter-clockwise to lower stud (refer to A).

  2. Once satisfied with all door panels, secure M8 studs with M8 washer and M8 nut (refer to B). The top of the stud must remain below the top face of the door panel.

fix14.png
  1. Secure side bracket forks by tightening side screws.
    Repeat this process for all door panels.

    Note: for depth adjustment loosen side screws x4, adjust panels and then retighten once satisfied.
    Note: further adjustment of door panels can be achieved by removing door panels then loosening the fixing screws for the hanging bracket and moving the bracket sideways to suit.
fix16.png
  • Was this article helpful?