Skip to main content
Fisher & Paykel Product Help

Installation Instructions

 

 

THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a qualified installer, service agent, or the gas supplier.
The use of suitable protective clothing/gloves is recommended when handling or installing this appliance.

 

Tools Needed for Installation (not supplied with the appliance)

Install Tools needed.PNG

 Dimensions and Clearances

  • The cooker must be installed no less than 2” (50 mm) away from any side walls which exceed the height of the cooktop.
  • The cabinetry surrounding the cooker must be made of heat-resistant material and must be able to withstand temperatures of 150 °F (65 °C) above room temperature.
  • Do not install the cooker near flammable materials (eg curtains).
  • If you stand the cooker on a pedestal, make sure you provide safety measures to keep it in place.

 Locating the Area for Electrical Connection

image.png
Grounded outlet: should be located from the left to the right side of the range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depending on feet regulation] from the floor. The electric cord with 4-prong ground plug (NEMA 14-50P) shall have a minimum length of 48” (1220 mm) beyond the back of the appliance.

 

The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (914 mm) high. There must be a minimum of 2” (50 mm) side clearance from the range to such combustible surfaces TO THE RIGHT above the 36” (914 mm) high countertop; or there must be a minimum of 2” (50 mm) side clearance from the range to such combustible surfaces TO THE LEFT above the 36” (914 mm) high countertop.  
image.pngv

Cooker Overall Dimensions

Height (without backguard)

MIN

MAX

 

35 2/32" (906 mm)

36 11/32" (923 mm)

Product Width 29 7/8" (759 mm)
Depth 24 13/64" (615 mm)
Backguard Height 3' (76 mm)

 

One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.

The maximum upper cabinet depth recommended is 13” (330 mm). Any wall cabinet above the range must be a minimum of 30” (762 mm) above the countertop with a minimum width of 30” (762 mm) and must be centered with the range. Side wall cabinets above the range must be a minimum of 18” (457 mm) above the countertop.

 Moving the Cooker

To prevent damaging the adjustable feet or lower trim, ensure the cooker is always lifted by two people.

Do not lift the cooker by the door handles. DO NOT DRAG the cooker. Lift the feet clear of the floor.

Take extra care not to damage the door sensor (top right of oven).

Install Corr Lift Cook.PNG

Correctly Lifting the Cooker

Install Incorr Lift Cook.PNG

Incorrectly Lifting the Cooker

Install Incorr Move Cook.PNG

Incorrectly Moving the Cooker

Fixing the Backguard 

It is mandatory to install the backguard. Before installing the cooker, assemble the backguard “C” .

  • The backguard “C” can be found packed with the cooker.
  1. Before assembling, remove any protective film/adhesive tape.
  2. Assemble the backguard “C” as shown
  3. Screw in the two screws “A”, interposing the spacers.
  4. Screw in the central screw “B”.

Install Assem backgard.PNG

Assembling the Backguard

 Leveling the Range

image.png

 

The range is equipped with 4 LEVELING FEET and may be leveled by screwing or unscrewing the feet. Follow the directions below.

image.pngimage.png

Anti-tip Stability Device Installation Instructions 

  1. The anti-tip bracket has to be attached as shown on figure below (only rear left side), it has to be fixed on the floor OR on the rear wall by no. 4 (four) suitable screws (not supplied). Alternatively the anti-tip bracket can also be fixed on the floor AND on the rear wall by no. 8 (eight) suitable screws (not supplied).
  2. After fixing the anti-tip bracket, slide range into place. Be sure the rear left foot slides under the anti-tip bracket attached.
image.png
YOU MUST USE STABILITY ANTI TIP BRACKET TO PREVENT UNIT FROM TIPPING.

Connecting the Power Supply Cable  

This cooker must be connected to the electricity supply only by an authorized person.

Your cooker is supplied with a certified 4 prong NEMA 14-50P power cord and should be plugged directly into a properly grounded socket. Do not under any circumstances cut or remove the forth (ground) prong from the power plug. Do not ground to a gas pipe. Do not have a fuse in the neutral or ground circuit.

Do not use an extension cord.

Check with a qualified electrical installer if you are not sure if the range is properly grounded.

If codes permit, and a separate ground wire is used, it is recommended that a qualified electrical technician determines the ground path and wire gauge are in accordance with local codes.

Be sure that the electrical connection and wire size are adequate and in conformance with:
ANSI/NFPA 70 latest addition and local codes and ordinances;

CSA standard C22.1, Canadian Electrical Code, Part 1 - latest edition and local codes and ordinances.

When a 4-wire, two phase 120/240V or 120/208V 60Hz AC only electrical supply is available a 50 amp maximum circuit protection is required, fused on both sides of the line.

Replacing the Power Cord

Replacements should only be made by qualified electrical technicians.

If replacing the power cord, use only a suitable UL or CSA approved one. Tighten the power cord using the power cord strain relief bracket supplied with the appliance. Allow enough slack to easily attach the cord terminals to the terminal block.

Voltage and Power Consumption

AC 120/240 V 60 Hz             10950 W MAX              46 A MAX
AC 120/208 V 60 Hz             10100 W MAX              48.84 A MAX
INDUCTION POWER = 7400 W MAX 

Install location of nameplate.PNG

Location of Nameplate

image.png

Wiring Diagram 

image.png

Electric Diagram Key

IU             INDUCTION UNIT
RSI          ROTARY SELECTOR INTERFACE
IUTB        INDUCTION UNIT TERMINAL BLOCK
IHTO       INDUCTION HOB THERMAL OVERLOAD
OL           OVEN LAMP
E61         RELAY
CE          CIRCULAR ELEMENT
GE          BROIL ELEMENT
TE          TOP ELEMENT
BE-INT   BOTTOM ELEMENT INT.
BE-EXT  BOTTOM ELEMENT EXT.
TPL        THERMOSTAT PILOT LAMP
DSPL      DOOR SAFETY PILOT LAMP
CF          COOLING FAN
OF          OVEN FAN
ER          ENERGY REGULATOR
DLM       DOOR LOCK MOTOR
SL/U       STATUS LOCK/UNLOCK

LPL         LINE PILOT LAMP
WD         WARMING DRAWER ELEMENT
ST           SAFETY THERMOSTAT
EL.P       ELECTRONIC PROGRAMMER
SD          DOOR STATUS, OPEN/CLOSED
ODL        OVEN DOOR LATCH
AS           AIR SWITCH

Connections on Programmer

PN/PL         SUPPLY
K1               PROGRAM THERMOSTAT RELAY1
K2               COOLING/OVEN FAN RELAY2
K3               DOOR LOCK/UNLOCK RELAY3
PHV            FUNCTION STATE
X0               THERMOSTAT ENCODER
X1               FUNCTIONS ENCODER
P4               PROBE
P5B            WIRES P5B(1)+P5B(2)+P5B(3)

  • Was this article helpful?