Skip to main content
Fisher & Paykel Product Help

Electrical Connection

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sure whether the range is properly grounded. Do Not ground to a gas pipe.

WARNING! 

Screen Shot 2018-01-07 at 9.32.05 PM.png

Electrical Shock Hazard

  • Plug into a grounded 3-prong outlet.
  • Do not remove ground prong.
  • Do not use an adapter.
  • Failure to follow these instructions can result in death, fire, or electrical shock.

WARNING VERY IMPORTANT

Before any operation of maintenance disconnect the appliance from the electrical main supply.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Check with a quali
fied electrician if you are not sure whether the range is properly grounded.

Do Not ground to a gas pipe.

A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is required.
A time-delay fuse or circuit breaker is recommended.
It is recommended that a separate circuit serving only this appliance be provided.

The outlet must be checked by a qualified electrician to see if it is wired with correct polarity.

This appliance, when installed, must be electrically grounded in accordance with local codes.

For your personal safety, this range must be grounded.
This range is equipped with a 3-prong ground plug.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code ANSI/ NFPA 70 latest edition and local codes and ordinances.
If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have a properly polarized and grounded, 3-prong outlet installed by a qualified electrician.

Screen Shot 2018-01-07 at 9.40.06 PM.png
Fig. 3.1

WIRING DIAGRAM

 


2018-01-08_1635.png

Electric Diagram Key

  • F1 SWITCH
  • EC ELECTRONIC CLOCK
  • MS SECURITY MICROSWITCH
  • S1 COOLING FAN FAILURE LAMP
  • LF OVEN LAMP
  • AS AIR FLOW SWITCH
  • V  FAN MOTOR
  • TL THERMAL OVERLOAD
  • PA IGNITION SWITCHES GROUP (COOKTOP BURNERS)
  • A  IGNITION COIL
  • OS  OVEN/BROIL IGNITION SWITCH
  • MU MAGNET UNIT - OVEN/BROIL THERMOCOUPLES
  • T0 OVEN/BROIL IGNITION SYSTEM
  • CF COOLING FAN MOTOR
  • M  TERMINAL BLOCK
  • T  EARTH CONNECTION

The manufacturer cannot be held responsible for possible inaccuracies due to printing or transcription errors in the present booklet.
The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without prior notice, without jeopardizing the essential functional and safety characteristics of the appliances.

  • Was this article helpful?