Installation instructions.

Proximity to Side Cabinets

Screen Shot 2018-01-08 at 2.55.27 PM.png
Fig. 1.1
  1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets.
    Range dimensions:

    • width: 23” 7/8 (606.5 mm)

    • depth: 24” 11/64 (614.1 mm)

    • height (without backguard): MIN 35” 17/32 (902.5 mm) - MAX 36” 7/32 (920 mm)

    • backguard (height): 4” 7/16 (113 mm)
      Gas line opening:
      Wall - 7” 9/32 (185 mm) from the floor; 5” 57/64 (150 mm) from the rear right side of the range.

      The electric cord with 4-prong ground plug (NEMA 14-50P) has a length of 72" ±1"1/2 (1830 mm ±38 mm).

      Grounded outlet should be located 7” 9/32 (185 mm) from the floor and 17” 31/32 (456.5 mm) from the rear left side of the range.

  2. The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (914 mm) high.

    There must be a minimum of 3” (76 mm) side clearance from the range to such combustible surfaces TO THE LEFT above the 36” (914 mm) high countertop; or there must be a minimum of 11” 13/16 (300 mm) side clearance from the range to such combustible surfaces TO THE RIGHT above the 36” (914 mm) high counter- top.

    One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.
  1. The maximum upper cabinet depth recommended is 13” (330 mm). Wall cabinet above the range must be a minimum of 30” (762 mm) above the countertop for a width of minimum 24” (609.6 mm): it has to be centred with the range. Side wall cabinets above the range must be a minimum of 18” (457 mm) above the countertop.

Gas and electrical connection

Screen Shot 2018-01-08 at 3.06.12 PM.png

Proximity to side cabinets


fixed52.png

Assembling the backguard

It is mandatory to install the backguard

Assemble the backguard as shown in figure 1.5:

  • Screw the 2 screws “A” interposing the spacers.
  • Screw the central screw “B”.
Screen Shot 2018-01-08 at 3.21.12 PM.png
Screen Shot 2018-01-08 at 3.26.30 PM.png

Levelling the backguard

The range is equipped with 4 LEVELLING FEET (supplied in a separate kit) and may be levelled by screwing or unscrewing the feet (fig. 1.8).

It is important to observe the directions of figures 1.6, 1.7a, 1.7b.

Screen Shot 2018-01-08 at 3.27.03 PM.png Screen Shot 2018-01-08 at 3.27.14 PM.png Screen Shot 2018-01-08 at 3.27.24 PM.png

YOU MUST USE STABILITY ANTI TIP BRACKET TO PREVENT UNIT FROM

Anti-tip stability device installation instructions

  1. The anti-tip bracket has to be attached as shown on figure below (only rear left side), it has to be fixed on the floor and on the rear wall by no. 4 (four) suitable screws (not supplied).

  2. After fixing the anti-tip bracket, slide range into place. Be sure the rear left foot slides under the anti-tip bracket attached.

Screen Shot 2018-01-08 at 3.47.16 PM.png