Connecting the Cooktop to the Main Power Supply

 

  • This cooktop must be connected to the mains power supply only by a suitably qualified person.
  • To connect the cooktop to the mains power supply, do not use adapters, reducers, or branching devices, as they can cause overheating and fire.
  • The power supply cable must not touch any hot parts and must be positioned so that its temperature will not exceed 165 oF / 75 oC at any point.

Before Connecting the Cooktop to the Mains Power Supply check that:

  • The domestic wiring system is suitable for the power drawn by the cooktop.
  • The voltage corresponds to the value given in the rating plate (refer Step 11 for location).
  • The power supply cable sections can withstand the load specified on the rating plate.

Power supply

CI122DTB*

CI244DTB

 

CI304DTB

 

CI365DTB

 

VOLTAGE

MAX. CURRENT DRAW MAX. LOAD MAX. CURRENT DRAW MAX. LOAD MAX. CURRENT DRAW MAX. LOAD MAX. CURRENT DRAW MAX. LOAD
208V 14A 3400W 26A 6400W 28A 6500W 39A 9600W
240V 16A 3840W 30A 7400W 32A 7400W 45A 11000W

*The CI122DTB comes supplied with a cable. This must be wired into a suitably rated plug, permanent connection outlet or power isolator.

Check with an electrician whether the domestic wiring system is suitable without alterations. Any alterations must only be made by a qualified electrician.

Connection diagrams  

CI244DTB, CI304DTB, CI365DTB


Screen Shot 2018-01-04 at 4.29.37 PM.png

CI122DTB


Screen Shot 2018-01-04 at 4.30.00 PM.png