Before connecting to the electricity, make sure that the:
- Specifications of the electrical system match with what is detailed on the serial number plate applied to the front of the oven.
- System has an effective ground connection compliant with current standards and laws.
The ground connection is required by law. The cable must not, at any point, reach a temperature greater than 122°F (50°C) above room temperature.
This oven must be connected to the electricity through a power supply cable and plug that is compatible with the outlet of the electrical system that powers this oven. If a fixed appliance does not have a power cord and plug, or another device that ensures disconnection from the mains, with an opening distance of the contacts that allows complete disconnection, such disconnection devices must be provided in the power supply mains conforming to the installation rules.
The omnipolar socket or switch must be easy to reach when the appliance is installed.
 |
The manufacturer declines all liability if the usual accident prevention standards and the above instructions are not followed. |
Max Power (W) |
Hz |
Voltage (V) |
Amps (A) |
3000 |
60 Hz |
240V |
12.5 |
2250 |
60 Hz |
208V |
10.8 |