Skip to main content
Fisher & Paykel Product Help

Installation instructions

Please read and follow the ‘Safety and warnings’ and ‘installation instructions’ sections carefully before using your rangehood.




Rangehood (1)



Installation instructions
User guide manual (1)



150mm ducting adapter
with non return flap (1)


125mm ducting adapter (1)


13mm screw (2)
 

 

Product and cabinetry cutout dimensions

 


Product Dimensions HP60 HP90

A.  Overall height of product (with ducting adapter)

350 (395) 315 (360)
B. Overall width of product 530 830
C. Overall depth of product 280 280
D. Thickness of flange 2 2
E. Width of chassis 492 792
F. Depth of chassis 255 255
G. Height of side of chassis 120 120
H. Width of top surface of chassis 220 220
I. Length of angled surface of chassis 260 335
J. Distance from centre of ducting outlet to back of chassis 145 145
K. Distance from centre of ducting outlet to side of chassis 245 395
L. Diameter of ducting outlet 150 150
M. Distance between centre of lights 80 285
N. Distance from centre of light to back of product 70 115
Length of power cord 950 950

 

Cabinetry Cutout Dimensions HP60 HP90
Overall width of cutout 500 800
Overall depth of cutout 260 260
O. Overall width of cutout Overall depth of cutout Base of brackets/clips to bottom of chassis min. 15 – max. 40 min. 15 – max. 40

Actual product dimensions may vary by ± 2 mm.
Please read the entire instructions before installing the rangehood.

Height of rangehood 

Minimum Clearances mm
P. Height top of cooktop to base of product Electric cooktop Gas cooktop min. 600 – max. 750
min.650 – max. 750

Rangehood installation height above the cooktop is the user’s preference. Lower installation heights will improve the efficiency of capturing cooking odours, grease, and smoke. This rangehood must be installed between the minimum and maximum dimensions indicated in the table above.

Venting options

Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air are fulfilled.
The rangehood can be installed to operate with the exhaust air ducted externally from the kitchen, or installed to operate with the exhaust air recirculating within the kitchen.

Ducted

For ducted installation it is recommended that 150 mm diameter, rigid or semi-rigid ducting is used. This will require a 160 mm (min) round hole in the ceiling or wall. Care should be taken to position the hole correctly.

For optimal efficiency use the shortest and straightest duct route possible and use rigid or semi-rigid ducting for reduced noise and increased airflow. Flexible metal ducting should only be used as a last resort (ie in difficult installations) and if used ensure that it is straight and smooth and extended as much as possible.

Recirculating

Where ducting outside is not a practical option, this rangehood can be installed to operate with the air recirculating. Carbon filters are required to remove odours from the air before it is channelled through the ducting back into the room or overhead bulkhead (refer to ‘Parts and accessories’ section). Ensure that the ducting outlet is not obstructed, even a partial obstruction will restrict the efficiency of the rangehood.

  • This appliance is heavy and requires two persons for unpacking and installation

  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards.

  • Failure to install the screws or fixing device in accordance with these instructions

    may result in electrical hazards

Wear gloves to protect against sharp edges.

The manufacturer is not liable for any damage caused by not following these instructions.

Installation

  1. Prepare for installation.
    Before installing your rangehood:

  • Please read the instructions carefully.
  • Unpack the rangehood and check that all functions are working.
  • Ensure that the voltage (V) and the frequency (Hz) indicated on the serial plate match the voltage and frequency at the installation site.
  • The stainless steel and glass surfaces of the rangehood are very easily damaged during installation if grazed or knocked by tools. Please take care to protect the surfaces during installation.
  • Protect the cooktop surface below with cardboard, or the like, to prevent damage occurring whilst the rangehood is being installed above.
  1. Fit the 150 mm ducting adapter with non return flap to the rangehood using the screws supplied.

  2. Provide an opening on the underside of the cupboard (see product and cabinetry cutout dimensions).

4. Remove the filters and face plate of the rangehood.






 

5. Connect duct and plug rangehood in.

6. Lift the rangehood and fit through the opening of the cupboard till the spring loaded brackets / clips hold the product in place.


7. Secure rangehood while tightening the 4 brackets / clips.


  • Was this article helpful?