Skip to main content
Fisher & Paykel Product Help

Installation Instructions

Contents of Packaging

Screen Shot 2018-01-03 at 2.33.10 PM.png

Ventilation hood (1)

Screen Shot 2018-01-03 at 2.35.30 PM.png
Installation instructions User guide manual (1)

Screen Shot 2018-01-03 at 2.36.02 PM.png
Power connection box (1)

Screen Shot 2018-01-03 at 2.36.16 PM.png
6” (152mm) diameter Ducting adapter with back draft damper (1)


Screen Shot 2018-01-03 at 2.36.36 PM.png
3/8” (10mm) Self tapping screw (4)


Product and Cabinetry Cutout Dimensions

Screen Shot 2018-01-03 at 2.47.06 PM.png
Screen Shot 2018-01-03 at 2.48.05 PM.png

Product Dimensions

inches (mm)

inches (mm)

A. Overall height of product

13 3/4” (350) 13 3/4” (350)

B. Overall height of product (with power connection box)

18 1/4” (463) 18 1/4” (463)

C. Overall width of product

20 7/8” (530) 32 11/16” (830)

D. Overall depth of product

11” (280) 11” (280)

E. Thickness of flange

1/16” (2) 1/16” (2)

F. Width of chassis

19 3/8” (492) 31 3/16” (792)

G. Depth of chassis

10 1/16” (255) 10 1/16” (255)

H. Height of side of chassis

7 11/16” (195) 7 11/16” (195)

I. Width of top surface of chassis

11 3/4” (298) 11 3/4” (298)

J. Length of angled surface of chassis

6 7/8” (175) 11” (280)

K. Distance from center of ducting outlet to back of chassis

3 1/8“ (80) 3 1/8” (80)

L. Distance from center of ducting outlet to side of chassis

9 5/8” (245) 15 9/16” (395)

M. Diameter of ducting outlet

6” (152) 6” (152)

N. Distance between center of lights

14 3/4” (375) 26 9/16” (675)

O. Distance from center of light to front of product

1 9/16” (40) 1 9/16” (40)

Cabinetry Cutout Dimensions HP24
inches (mm)
inches (mm)
    Overall width of cutout 19 11/16” (500)19 11/16" (500) 31 1/2" (800)
    Overall depth of cutout 10 1/4" (260) 10 1/4" (260)
Base of brackets/clips to bottom of chassisBase of brackets/clips to bottom of chassisP. Base of brackets/clips to bottom chassis min. 9/16" - max. 1 9/16" (min. 15 - max. 40) min. 9/16" - max. 1 9/16" (min. 15 - max. 40)min. 9/16" - max. 1 9/16" (min. 15 - max. 40)


  • Actual product dimensions may vary by ± 1/16” (2 mm).
  • Please read the entire instructions before installing the ventilation hood.


Height of Ventilation Hood


Screen Shot 2018-01-03 at 3.10.33 PM.png

Minimum Clearances

inches (mm)

Q. Height top of cooktop to base of product

min. 26” – max. 30” (min 660 – max. 762)

This ventilation hood must be installed no lower than the minimum height indicated in the table above. Minimum installation height may be greater if required by the cooktop manufacturer or safety and warning section of this user guide. Installation at the minimum height will improve the efficiency of capturing cooking odors, grease and smoke. Installation at the maximum height improves user ergonomics by offering increased head room.

  • To reduce the risk of fire, use only metal ductwork. Do not use flexible plastic ducting
  • To reduce risk of fire and to properly exhaust air, be sure to duct air outside – do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

Venting Options

Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air are fulfilled.

The ventilation hood can be installed to operate with the exhaust air ducted externally from the kitchen.


For ducted installation it is recommended that 6” (152 mm) diameter, rigid or semi-rigid ducting is used. This will require a 6 5/16” (160 mm) (min) round hole in the ceiling or wall. Care should be taken to position the hole correctly.

For optimal efficiency use the shortest and straightest duct route possible and use rigid or semi-rigid ducting for reduced noise and increased airflow. Flexible metal ducting should only be used as a last resort (ie in difficult installations) and if used ensure that it is straight and smooth and extended as much as possible.

  • This appliance is heavy and requires two persons for unpacking and installation

  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards.

  • Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards

Wear gloves to protect against sharp edges. Wear gloves to protect against sharp edges.

  The manufacturer is not liable for any damage caused by not following these instructions.



1. Prepare for Installation

Before installing your ventilation hood:

  • Please read the instructions carefully.
  • Unpack the ventilation hood and check that all functions are working.
  • Ensure that the voltage (V) and the frequency (Hz) indicated on the serial plate match the voltage and frequency at the installation site.
  • The stainless steel surfaces of the ventilation hood are very easily damaged during installation if grazed or knocked by tools. Please take care to protect the surfaces during installation.
  • Protect the cooktop surface below with cardboard, or the like, to prevent damage occurring whilst the ventilation hood is being installed above.

2. Attach ducting adapter and power connection box to the ventilation hood

  • Place the ducting adapter onto the ventilation hood and screw it in place using 3/8” (10 mm) screws.
  • Place the power connection box onto the ventilation hood and screw it in place using 3/8” (10 mm) screws.
  • Follow wiring instructions described in the ‘Electrical connection’ section.

3. Provide an opening on the underside of the cupboard (see product and cabinetry cutout dimensions).

  • It is also recommended that the cupboard has a door or service panel that can be easily opened to access the power connection box

 4. Remove the filters and face plate of the ventilation hood.



Remove the filters and face plate of the ventilation hood.

5. Lift the ventilation hood and fit through the opening of the cupboard till the spring loaded brackets / clips hold the product in place.


Screen Shot 2018-01-03 at 3.31.18 PM.png

6. Secure ventilation hood while tightening the 4 brackets / clips.


Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards and the unit must be grounded.

7. Electrical Connection 

  • Run three wires, two for the power supply and one for the ground wire, from the power connection box on the ventilation hood to a power connection point near the installation.
  • Open the power connection box on the ventilation hood and secure the power conductor with a cULus listed strain relief (not included).

  • Connect the power conductors to the conductors for the ventilation hood, black to black and white to white.

  • Connect the grounding wire (green or bare) to the ground conductor (green) of the ventilation hood power connection box.

  • Secure all the connections with cULus listed wire nuts.

  • Replace the power connection box cover.

Screen Shot 2018-01-03 at 3.36.13 PM.png