General Information

General Information on the installation of this appliance.

Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - Latest Edition, CAN/CGA-B149.1 or CAN/ CGA-B149.2.

Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or with local codes where applicable.

Installation in Recreational Park Trailers: installation must conform with state or other codes or, in the absence of such codes, with the Standard for Recreational Park Trailers, ANSI A119.5.

To eliminate risk of burns or fire by reaching over heated surface units, cabinet storage located above the surface units should be avoided.

Air curtain or other overhead range hoods, which operate by blowing a downward air flow on to a range, shall not be used in conjunction with gas ranges other than when the hood and range have been designed, tested and listed by an independent test laboratory for use in combination.

WARNING!!  This appliance shall not be used for space heating. This information is based on safety considerations.

AlI openings in the wall behind the appliance and in the floor under the appliance shall be sealed.

Keep appliance area clear and free from combustible mate- rials, gasoline, and other flammable vapors.

Do not obstruct the flow of combustion and ventilation air.

Disconnect the electrical supply to the appliance before servicing.

When removing appliance for cleaning and/or service;

Shut off gas at main supply.

Disconnect AC power supply.

Disconnect gas line to the inlet pipe.

Carefully remove the range by pulling outward.

CAUTION: Range is heavy; use care in handling.

 

Electrical Requirement 

Electrical installation should comply with national and local codes.

Air Supply and Ventilation 

The installer must refers to local/national codes.

Gas Manifold Pressure

Natural gas - 4.0” W.C.P.

LP/Propane - 11.0” W.C.P.

The misuse of oven door (e.g. stepping, sitting, or leaning on them) can result in potential hazards and/or injuries.

When installing or removing the range for service, a rolling lift jack should be used. Do not push against any of the edges of the range in an attempt to slide it into or out of the installation. Pushing or pulling a range (rather than using a lift jack) also increases the possibility of bending the leg spindles or the internal coupling connectors.

 

WARNING!!

Electrical grounding instructions

The range must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70-latest edition, in Cana- da Canadian Electrical Code.

Installation should be made by a Licensed electrician.

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

If an external electrical source is utilized, the installation must be electrically grounded in accordance with local codes or, in the absence of local codes, with the national Electrical Code, ANSI/ NFPA 70.

This appliance is equipped with a three-prong grounding plug (NEMA 5-15P) for your protection against shock hazard and should be plugged directly into a properly grounded socket.

Do not under any circumstances cut or remove the third (ground) prong from the power plug.

Replacement Parts

Only authorized replacement parts may be used in performing ser- vice on the range. Replacement parts are available from factory authorized parts distributors. Contact the nearest parts distributor in your area.

  • Was this article helpful?