Unpacking and Examining Your Oven

Remove: all packing materials from inside the oven cavity; however, DO NOT REMOVE THE WAVEGUIDE COVER, which is located on the right cavity wall. Read enclosures and SAVE this manual.

Check the oven for any damage, such as misaligned or bent door, damaged door seals and sealing surfaces, broken or loose door hinges and latches and dents inside the cavity or on the door. If there is any damage, do not operate the oven and contact your dealer or DCS AUTHORIZED SERVICER.

Screen Shot 2018-01-09 at 4.11.50 PM.png

Choosing a Location for Your Oven on the Counter

You will use the oven frequently so plan its location for ease of use. It’s wise, if possible, to have counter space on at least one side of the oven. Allow at least 2 inches on the sides, top and at the rear of the oven for air circulation.

Choosing a Location for Your Oven if Built-in

Your oven can be built into a cabinet or wall by itself or above the models listed below using a DCS by Fisher & Paykel branded or Fisher & Paykel branded Microwave Accessory Trim Kit (MOTTK). To order the Trim Kit, contact Customer Care.

Models above which the MO24-SS microwave oven can be built in:

Ovens:
WOSU-30 (DCS by Fisher & Paykel) OB30SDEPX (Fisher & Paykel)

Warming drawers:
WDU-30 (DCS by Fisher & Paykel) WDUI-30 (DCS by Fisher & Paykel) OD30WDX1 (Fisher & Paykel)

Do not build in above any other gas or electric wall oven.

M1.JPG

 

Over Oven Installation Over Warming Drawer Installation

 

Screen Shot 2018-01-09 at 4.09.34 PM.png

 

Screen Shot 2018-01-09 at 4.09.55 PM.png

 

See Trim Kit Installation Instructions for proper location when building in above the specified wall ovens. Carefully follow both the wall oven installation instructions and Trim Kit instructions.

The opening in the wall or cabinet must be within the following dimensions:

  1. HEIGHT : 17" + 1/16", -0

  2. WIDTH : 24 3/4" + 1/16", -0

  3. DEPTH : minimum 20"

Outlet should NOT be in the shaded area as indicated.

  1. If the dimension of DEPTH (C) is more than 21", the outlet location may be any area on the rear wall.

  2. The floor of the opening should be constructed of plywood strong enough to support the weight of the oven and floor  load (about 100 pounds).

 

 

fixed107.png


The floor should be level for proper operation of the oven. Be sure to check the local building code as it may require that the opening be enclosed with sides, ceiling and rear partition. The proper functioning of the oven does not require the enclosure.

The Trim Kit includes all the necessary parts (including simulated frames that match the MO-24SS microwave oven) and easy-to-follow instructions for installation as well as location of the power supply.

The ease of assembly for these kits will allow installation into an existing wall opening in less than an hour (if power outlet is already properly located).

All it takes are four steps and a Phillips screw driver.