Skip to main content
Fisher & Paykel Product Help

Installation Instructions

 

 

Specifications

  • The cabinet depth from the outer edge of the face frame to the inside back of the cabinet or wall should be at least 24” (see Fig. 1).
  • The warming drawer should be installed into a base cabinet with minimum outside dimensions of 13-1/4” high by 30” wide by 24” deep.
  • Power supply required: 120Volts AC; 5 amp min., 15 amp maximum circuit requirement.

 

Cut Out Dimensions

Specifications_Fig 1.PNG

Fig.1

Warming Drawer Dimensions (Front View)

Specifications_Fig 2.PNG

Fig.2

WDV2-30 Dimensions (Side View)

Specifications_Fig 3.PNG

Fig.3

WDVI-30 Dimensions (Side View)

Specifications_Fig 4.PNG

Fig.4

WDVI-30 Dimensions (Custom Panel)

Specifications_Fig 4a.PNG

Fig.4a

 

Mounting Installation

  • The lower rear corners of the cabinet need to provide proper support to the back of the warming drawer and the anti-tip mounting clips. A 120 volt AC outlet should be located no further than 36 inches from the back center of the warming drawer.
  • The bottom rear section of the cabinet should be made of solid plywood or two 2x4 beams.  It holds the anti-tip mounting clips and supports the weight of the warming drawer, which is 90 lbs. (see Figs. 5 and 6). If two 2x4 beams are used, the distance between their centers must be 20” to be able to secure the Warming Drawer.

STEP 1

Use the screws provided and attach the mounting clips. They must be installed for anti-tip safety to the
bottom support at the back. See placement dimensions in the figures below (see Figs. 5 and 6).


STEP 2

Plug power cord into AC outlet. Slide the body onto the anti-tip mounting clips (see Fig. 6).


STEP 3

Use the two supplied 1-1/2” long screws through the two embossed holes (see Fig. 7) to secure the
front of the warming drawer.

Mounting Installation_fig.5.PNG

Fig.5

Mounting Installation_fig.6.PNG

Fig.6

Mounting Installation_fig.7.PNG

Fig.7

 

Custom Panel Installation of the Integrated Warming Drawer (WDUI/WDVI-30)

STEP 1

Remove drawer as per instructions (see section ‘Care and maintenance’).


STEP 2

Check the dimensions of the front face (see Fig. 8).


STEP 3

Cut the custom panel to the desired dimensions, knowing that the panel must cover the paper front template plus 1/8” on all four sides for a good presentation. The thickness of the custom panel must be greater than 9/16” to allow for clearance for the tips of the screws holding the drawer when the custom panel is mounted.


STEP 4

Center the provided paper front template on the back of the custom panel to drill or cut the clearance areas for the hardware holding the drawer.

Note-Icon.png The drill sizes and call outs are on the template.

STEP 5

Fasten the custom panel to the front face with the supplied screws as shown in Fig. 8.

 

Custom Panel Install Fig.8.PNG

Fig.8

 

 

Cabinet Installation

Double Wall Oven & Warming Drawer Installation

Cab Install_Fig.9.PNG

Fig.9

Single Wall Oven, Microwave & Warming Drawer Installation

Cab Install_Fig.10.PNG

Fig.10

Note-Icon.png **The floor of the opening should be constructed of plywood strong enough to support the weight of the oven (or use 2 x 4 constructions – see Fig. 1)

 

 

 

 

  • Was this article helpful?