WARNING! 

Electric Shock.PNG

Electric Shock Hazard

  • Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply.
  • Connection to a good ground wiring system is absolutely essential and mandatory.
  • Alterations to the domestic wiring system must only be made by a qualified electrician 
  • Failure to follow this advice may result in electrical shock or death.

WARNING! 

Fire Hazard.PNG

Fire Hazard

  • Do not use adapters, reducers, or branching devices to connect this appliance to the mains power supply.
  • Failure to follow this advice may result in overheating, burning, or fire.

WARNING! 

Cut Hazard.PNG

Cut Hazard

  • Take care - some panel edges are sharp.
  • Failure to use caution could result in injury or cuts.

 

Important Safety Instructions!

  • Save these instructions for the local inspectors use.
  • To avoid hazard, follow these instructions carefully before installing or using this appliance.
  • Please make this information available to the person installing the appliance - doing so could reduce your installation costs.
  • This oven is to be installed and connected to the electricity supply only by an authorized person.
  • If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that the socket cable section is suitable for the electricity drawn by the oven.
  • The oven must be grounded.
  • Installation must comply with your local building and electricity regulations.
  • This appliance must be installed and connected to the mains power supply only by a suitably qualified person according to these installation instructions and in compliance with
  • any applicable local building and electricity regulations. Failure to install the appliance correctly could invalidate any warranty or liability claims.
  • If the power supply cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard.
  • A circuit breaker is recommended.
  • Do not use adaptors, reducers or branching devices to connect the oven to the mains electricity supply, as they can cause overheating and burning.
  • Make sure the cavity is completely sealed with no gaps. This is to ensure the oven cooling system functions correctly.

 

Electrical Requirements

  • Connect oven with copper wire only.
  • Do not cut the conduit.
  • A U.L. listed conduit connector must be provided at the junction box.
  • Do not ground to a gas pipe.
  • Do not have a fuse in the grounding or neutral circuit.
  • Fuse both sides of the line.
  • A time delay fuse or circuit breaker is recommended. If using a time delay fuse, then fuse both sides of the line.
  • Flexible armored cable from the appliance should be connected directly to the junction box.
  • Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire).
  • If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path and wire gauge are in accordance with local codes.

 

Important-Icon.png SAVE THESE INSTRUCTIONS