These are instructions for Hard Wiring prior to installation (optional).

A. Remove the Lower Drawer

Screen Shot 2018-01-05 at 1.34.48 PM.png

Press the release tabs in on either side and push back to release drawer from runners. Lift drawer off runners.

To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.

Screen Shot 2018-01-05 at 1.35.01 PM.png

B. Remove the Access Cover & Remove Power

Screen Shot 2018-01-05 at 1.39.34 PM.png

  1. With a flat-bladed screwdriver, push in the clips and slide out the access cover.
  2. Unscrew the electronics module cover.
  3. Carefully pull out the electronics module and rest on the chassis base out of the way.
  4. With a screwdriver, unclip the plastic harness cover and hinge open.
  5. Slide the terminal block cover sideways to unlock and hinge open to access the terminal block.
  6. Unscrew the Live, Neutral and Earth wires as shown.
  7. Unscrew the three screws on the base as shown and remove the cord from the product.
Screen Shot 2018-01-05 at 1.45.02 PM.png

C. Terminate Mains Wiring as shown and Replace Module and Covers

Screen Shot 2018-01-05 at 1.48.20 PM.png

Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics module.

Screen Shot 2018-01-05 at 1.48.33 PM.png

Screen Shot 2018-01-05 at 1.48.53 PM.png

  1. Fit a suitable cable clamp for the conduit through the metal knockout. Ensure wiring is routed through or under under housing ribs.
  2. Screw down the Live, Neutral and Earth wires correctly.
  3. Push the plastic harness cover back over. It should clip back into place
  4. Fold down and slide back the terminal block cover.
  5. Refit the electronics module back into position, being careful of wiring.
  6. Replace the screw securing the electronics module.
  7. Slide the access cover back, ensuring the 2 clips shown are fully locked in place.
NOTE: Use copper conductors only.


D. Refit the Drawer onto the Runners & Close

Screen Shot 2018-01-05 at 1.59.48 PM.png