Skip to main content
Fisher & Paykel Product Help

Optionally Hard Wiring Prior to Installation

 

 

 

A.  Remove the Lower Drawer

To prevent kinked hoses 

Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.

OPT Hardwiring_3A Remove lower drawer.PNG

Press the release tabs in on either side and push back to release drawer from runners. Lift drawer off runners.

 

B.  Remove the Access Cover & Remove Power

  1. With a flat-bladed screwdriver, push in the clips and slide out the access cover.
  2. Unscrew the electronics module cover.
  3. Carefully pull out the electronics module and rest on the chassis base out of the way.
  4. With a screwdriver, unclip the plastic harness cover and hinge open.
  5. Slide the terminal block cover sideways to unlock and hinge open to access the terminal block.
  6. Unscrew the Live, Neutral and Earth wires as shown.
  7. Unscrew the three screws on the base as shown and remove the cord from the product

OPT Hardwiring_3B Remove Access Cover_power.PNG

.

 

C.  Terminate Mains Wiring as Shown & Replace Module & Covers

OPT Hardwiring_3C Terminate Mains Wiring_Replace Module & Covers.PNG

Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics module.  
  1. Fit a suitable cable clamp for the conduit through the metal knockout.  Ensure wiring is routed through or under under housing ribs.
  2. Screw down the Live, Neutral and Earth wires correctly.
  3. Push the plastic harness cover back over. It should clip back into place
  4. Fold down and slide back the terminal block cover.
  5. Refit the electronics module back into position, being careful of wiring.
  6. Replace the screw securing the electronics module.
  7. Slide the access cover back, ensuring the 2 clips shown are fully locked in place.

Use copper conductors only.

 

D.  Refit the Drawer onto the Runners & Close

1 & 2.  Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.

  1. Lift or rotate counter-clockwise the drawer back onto the drawer runners on either side.
  2. Pull the release tabs forward on both sides 4” (100 mm). Ensure the tabs are fully pulled forward and click into place.

OPT Hardwiring_3D Refit the Drawer onto the Runners and close.PNG

 

 

 

 

  • Was this article helpful?