Cavity Preparation
Cavity Dimensions
Property (mm) |
RS90A |
---|---|
|
1800 |
|
900 |
|
650 |
Rear View Of Cavity
Electrical Specifications
RS90A |
RS90AU |
|
---|---|---|
Supply |
230 VAC, 50 Hz |
230 VAC, 50 Hz |
Service |
10 amp circuit |
10 amp circuit |
Plumbing Specifications
RS90A |
RS90AU |
|
---|---|---|
Supply |
– |
1⁄2” BSP threaded water connection 6.35 mm PEX tubing |
Pressure |
– |
Minimum 22 psi (150 kPa) Maximum 120 psi (827 kPa) @ 20°C |
Recommended that the electrical & water connection be located in an adjacent cabinet to either side of the fridge or above the fridge cavity.
Do not locate water or electricity in this area, keep clear of connections.
Central area can only fit water outlet and electrical plug if they are placed within a recessed cavity.
* In this location the water tap needs to be recessed into the wall, the recess must allow for an 80 mm bend radius for the water tube.