Skip to main content
Fisher & Paykel Product Help

Cavity Preparation

Details the cavity dimensions of your fridge.

2017-08-02_1428.png

Cavity Dimensions

Property (mm)

RS90A
RS90AU

  1. Overall height of cavity

1800

  1. Overall width of cavity

900

  1. Overall depth of cavity

650

 

2017-08-02_1429.png
Rear View Of Cavity
 

Electrical Specifications

 

RS90A

RS90AU

Supply

230 VAC, 50 Hz

230 VAC, 50 Hz

Service

10 amp circuit

10 amp circuit

Plumbing Specifications 

 

RS90A

RS90AU

Supply

1⁄2” BSP threaded water connection 6.35 mm PEX tubing

Pressure

Minimum 22 psi (150 kPa) Maximum 120 psi (827 kPa) @ 20°C

Note-Icon.png

Recommended that the electrical & water connection be located in an adjacent cabinet to either side of the fridge or above the fridge cavity.

2017-08-02_1436.png Do not locate water or electricity in this area, keep clear of connections.

2017-08-02_1437.png Central area can only fit water outlet and electrical plug if they are placed within a recessed cavity.

* In this location the water tap needs to be recessed into the wall, the recess must allow for an 80 mm bend radius for the water tube.