Skip to main content
Fisher & Paykel Product Help

Installation instructions

Please read and follow the ‘Safety and warnings’ and ‘installation instructions’ sections carefully before using your rangehood.
 

Contents of packaging

Rangehood (1)

Installation instructions User guide manual (1)

Chimney (1)

Upper chimney (1)

Upper chimney bracket (1)

Chimney bracket (1)

Ducting adapter (150 mm Ø)
(1)

Expansion plug (8)

30 mm self tapping screw (8)

10 mm self tapping screw (4)

   

Product dimensions

 
 

 

Property (mm)

HC60

HC90

HC120

  1. Overall height of product

 

595 – 1035

 

595 – 1035

595 – 1035

  1. Overall width of product

598

898

1198

  1. Overall depth of product

500

500

500

  1. Height of hood

55

55

55

  1. Height of stainless strip

27

27

27

  1. Width of chimney

320

320

320

  1. Depth of chimney

290

290

290

  1. Distance from centre of ducting outlet to back of product

105

105

105

  1. Distance from centre of ducting outlet to side of chimney

160

160

160

  1. Diameter of ducting outlet

150

150

150

  1. Distance between centre of lights

230

230

230

  1. Distance from centre of lights to back of product

45

45

45

Length of power cord

1500

1500

1500

 

 

Actual product dimensions may vary by ± 2 mm.

Please read the entire instructions before installing the rangehood.

Height of rangehood 

Installation Dimensions

Property

(mm)

  1. Installation height
    Ducted
    Recirculation

min. 635 – max. 1035
min. 675 – max. 1035

  1. Height top of cooktop to base of product
    Electric cooktop
    Gas cooktop

min. 600 – max. 750
min. 650 – max. 750

Rangehood installation height above the cooktop is the user’s preference. Lower installation heights will improve the efficiency of capturing cooking odours, grease, and smoke. This rangehood must be installed between the minimum and maximum dimensions indicated in the table above.

Venting options

Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air are fulfilled.

The rangehood can be installed to operate with the exhaust air ducted externally from the kitchen, or installed to operate with the exhaust air recirculating within the kitchen.

Ducted

For ducted installation it is recommended that 125 mm diameter, rigid or semi-rigid ducting is used. This will require a 135 mm (min) round hole in the ceiling or wall. Care should be taken to position the hole correctly.

For optimal efficiency use the shortest and straightest duct route possible and use rigid or semi-rigid ducting for reduced noise and increased airflow. Flexible metal ducting should only be used as a last resort (ie in difficult installations) and if used ensure that it is straight and smooth and extended as much as possible.

Recirculating

To enable the product to operate with the air recirculating, please purchase a recirculation diverter and carbon filters (refer to the ‘Parts and accessories’ section). The recirculation diverter is installed after a short length of ducting and is required to channel the air out the side vents at the top of the chimney and the carbon filters are required to remove odours.

A ducting hole is not required in the wall or ceiling if the rangehood is installed to operate with exhaust air recirculating.

  • This appliance is heavy and requires two persons for unpacking and installation
  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards.
  • Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards

Wear gloves to protect against sharp edges.

The manufacturer is not liable for any damage caused by not following these instructions.

Installation

  1. Prepare for installation.
    Before installing your rangehood:

  • Please read the instructions carefully.
  • Unpack the rangehood and check that all functions are working.
  • Ensure that the voltage (V) and the frequency (Hz) indicated on the serial plate match the voltage and frequency at the installation site.
  • Check that the area behind the installation surface to be drilled is clear of any electrical cables or pipes, etc.
  • The stainless steel and glass surfaces of the rangehood are very easily damaged during installation if grazed or knocked by tools. Please take care to protect the surfaces during installation.
  • Protect the cooktop surface below with cardboard, or the like, to prevent damage occurring whilst the rangehood is being installed above.
  • Temporarily mark the height of the bottom of the rangehood and the centre of the cooktop on the wall according to the information given in the ‘Installation instructions – Height of rangehood’ section.
  • The wall used for mounting the rangehood should have sufficient strength and a flat surface.
  1. Attach chimney brackets and hood mounting screws

  • Attach the chimney bracket and upper chimney bracket (if using the upper chimney) in the locations shown in Fig.2 and 3. Use the 30 mm screws and expansion plugs if attaching to masonry.
  • Attach the upper hood mounting screws in the locations shown in Fig.2 and 3. Use the 30 mm screws and expansion plugs if attaching to masonry. Ensure that there is a 2 mm gap between the screw head and the wall – see Fig.1.

Fig.1


Fig.2

Product Dimensions

Property (mm)

HC60

HC90

HC120

  1. Lower rangehood attachment point width

420

580

900

  1. Chimney bracket attachment point height

559

559

556

  1. Upper rangehood attachment point height

286

286

288

  1. Lower rangehood attachment point height

36

36

42.5

Fig.3 

  1. Attach ducting adapter

  • Place the ducting adapter onto the hood and screw it in place using the 10 mm screws.

  1. Attach hood to wall

  • Remove filters and easy clean plate from hood as shown in Fig.4.

Fig.4

Fig.5

  • Hang hood off upper hood mounting screws with 2 mm gap. Hang off the keyhole attachment points on the back of the hood (see Fig.5). Tighten screws.
  • Attach lower hood mounting screws to fix hood to wall.
  • Reattach easy clean plate and filters.
  1.  Attach ducting
  • Attach ducting to ducting adapter using aluminium duct tape and vent outside.

  1. Attach chimney

  • Bend the tabs on the chimney (A).
  • Place chimney around the hood chassis and hang off the bracket (B).
  • Extend the upper chimney and attach to the chimney bracket with 10 mm screws (C).