This cooktop requires adequate supply of cool air to fully function.
The base of the cooktop must have direct unrestricted ventilation to the room where the cooktop is installed. Follow the requirements shown.  

Property (mm)

CI302DTB

CI603DTB

CI604DTB

CI754DTB

CI905DTB

  1. Minimum clearance from rear edge of cutout to nearest combustible surface

30

30

30

30

30

  1. Minimum clearance from glass surface to rangehood

650

650

650

650

650

  1. Minimum clearance from side edges of cutout to nearest combustible surface

30

30

30

25

25

  1. Minimum clearance from benchtop to overhead cabinet not directly above the cooktop

450

450

450

450

450

  1. Minimum clearance below top of benchtop to: Rear top of oven* installed below cooktop or cabinetry

65

65

65

65

65

Note-Icon.png

The oven installed below the cooktop MUST have a cooling fan.