Skip to main content
Fisher & Paykel Product Help

Clearance Dimensions

Details the various clearance dimensions of your cooktop.

Property (mm)

CG604DX

CG905DX

  1. minimum clearance from left edge of cutout to nearest combustible surface
130 130
  1. minimum clearance from right edge of cutout to nearest combustible surface
115 115
  1. minimum clearance from rear edge of cutout to:
    nearest combustible surface
    nearest non-combustible surface
160
45
160
45
  1. minimum height of non-combustible material when used on adjacent walls
150 150
  1. minimum clearance from cooktop surface to:
    rangehood
    any other overhead exhaust fan
    downward facing combustible surface
    downwards-facing tiled or fi re resistant surface
650
800
650
500
650
800
650
500
  1. minimum clearance below top of benchtop to:
    combustible surface
    Fisher & Paykel oven or nearest non-combustible surface
70
65
70
65
  1. minimum distance from right edge of cooktop to gas connection point on wall
    (if using a fl exible hose)
250 250
  1. distance from fl oor to gas connection point on wall (if using a flexible hose)
min. 800 - max. 850 min. 800 - max. 850
  1. maximum overall depth of overhead cabinetry
600 600

Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of the product, on the right-hand side. It should be accessible with the product installed.

  • Was this article helpful?