Skip to main content
Fisher & Paykel Product Help

Clearance Dimensions

2017-08-02_1324_480-fixed.jpg

ISO

2017-08-02_1325.png

FRONT

Property

Size (mm)

  1. Minimum clearance from left edge of cutout to nearest combustible surface

100

  1. Minimum clearance from right edge of cutout to nearest combustible surface

100

  1. Minimum clearance from rear edge of cutout to:
    • Nearest combustible surface
    • Nearest non-combustible surface

115
35

  1. Minimum height of non-combustible material when used on adjacent walls

150

  1. Minimum clearance from cooktop surface to:
    • Rangehood
    • Any other overhead exhaust fan
    • Downward facing combustible surface
    • Downwards-facing tiled or fire resistant surface

650
800
650
500

  1. Minimum clearance below top of benchtop to:
    • Combustible surface
    • Fisher & paykel oven or nearest non-combustible surface

81
81

  1. Minimum distance from right edge of cooktop to gas connection point on wall (if using a flexible hose)

250

  1. Distance from floor to gas connection point on wall (if using a flexible hose)

min. 800 - max. 900

  1. Maximum overall depth of overhead cabinetry

600

Note-Icon.png

Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of the product, on the right-hand side. It should be accessible with the product installed.