Gas Rate Summary
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
All appliances are factory set for either Natural Gas or ULPG and are not convertible. Check the ‘Gas type’ sticker on the base of the appliance.
CG301D, CG302D, CG451D, & CG603D
NG ULPG (1.00 kPa)*
CG301D | Dual Wok | Jet size (mm) | 1.45 1.45 0.70 |
---|---|---|---|
Nominal rating (MJ/h) | 21.50 | ||
CG302D | Aux | Jet size (mm) | 1.00 |
Nominal rating (MJ/h) | 5.00 | ||
Semi-Rapid | Jet size (mm) | 1.35 | |
Nominal rating (MJ/h) | 8.80 | ||
CG451D |
Dual Wok | Jet size (mm) |
1.43 |
Nominal rating (MJ/h) |
21.0 |
||
CG603D | Semi-Rapid | Jet size (mm) |
1.30 |
Nominal rating (MJ/h) |
8.40 |
||
Dual Wok | Jet size (mm) |
1.26 |
|
Nominal rating (MJ/h) |
16.60 |
ULPG (2.75 kPa)*
CG301D | Dual Wok | Jet size (mm) | 0.80 0.80 0.50 |
---|---|---|---|
Nominal rating (MJ/h) | 21.50 | ||
CG302D | Aux | Jet size (mm) | 0.64 |
Nominal rating (MJ/h) | 5.00 | ||
Semi-Rapid | Jet size (mm) | 0.80 | |
Nominal rating (MJ/h) | 8.10 | ||
CG451D |
Dual Wok | Jet size (mm) | 0.80 0.80 0.50 |
Nominal rating (MJ/h) | 20.5 | ||
CG603D | Semi-Rapid | Jet size (mm) | 0.76 |
Nominal rating (MJ/h) | 7.50 | ||
Dual Wok | Jet size (mm) | 0.73 0.73 0.50 |
|
Nominal rating (MJ/h) | 16.80 |
CG604D, CG752D, CG903D, & CG905D
NG ULPG (1.00 kPa)*
Aux | Jet size (mm) | 0.85 |
---|---|---|
Nominal rating (MJ/h) | 3.60 | |
Semi-Rapid | Jet size (mm) | 1.30 |
Nominal rating (MJ/h) | 8.30 | |
Rapid | Jet size (mm) | 1.55 |
Nominal rating (MJ/h) | 11.50 | |
Mini Wok | Jet size (mm) | 1.55 |
Nominal rating (MJ/h) | 11.70 | |
Dual Wok | Jet size (mm) | 1.30 1.30 0.70 |
Nominal rating (MJ/h) | 18.00 |
ULPG (2.75 kPa)*
Aux | Jet size (mm) | 0.55 |
---|---|---|
Nominal rating (MJ/h) | 3.60 | |
Semi-Rapid | Jet size (mm) | 0.76 |
Nominal rating (MJ/h) | 7.50 | |
Rapid | Jet size (mm) | 0.94 |
Nominal rating (MJ/h) | 11.50 | |
Mini Wok | Jet size (mm) | 0.94 |
Nominal rating (MJ/h) | 11.70 | |
Dual Wok | Jet size (mm) | 0.76 0.76 0.50 |
Nominal rating (MJ/h) | 18.00 |
*Nominal pressure with at least one large burner on High.