Skip to main content
Fisher & Paykel Product Help

Flush Mounting Installation (Optional)

We do not recommend flush mounting and sealing as servicing requires the cooktop to be removed from the benchtop. The owner carries all risk for flush mounting the cooktop.
Caution-Icon.png

We do not recommend flush mounting and sealing as servicing requires the cooktop to be removed from the benchtop. The owner carries all risk for flush mounting the cooktop. The owner must ensure the cooktop has been cut out from the benchtop before servicing can be carried out. Fisher & Paykel will not be liable for any costs associated with removing or replacing a flush-mounted and/or sealed-in product, nor for repairing any damage that may be incurred by doing this.

2017-07-27_1325.png
2017-07-27_1329.png
2017-07-27_1326.png 2017-07-27_1328.png 2017-07-27_1330.png
Note-Icon.png

Gas inlet connection is located in the rear right corner.

Property (mm)

CG301D

CG302D

CG451D

CG603D

CG604D

CG752D

CG903D

CG905D

  1. Overall height of product (excluding burners, dials and pan supports)

64

64

64

64

64

64

64

64

  1. Overall width of product

300

300

450

600

600

750

900

900

  1. Overall depth of product

530

530

530

530

530

450

450

530

  1. Height of chassis (below top of bench)

64

64

64

64

64

64

64

64

  1. Width of chassis

256

256

406

555

555

706

856

856

  1. Depth of chassis

486

486

486

486

486

410

410

486

  1. Overall width of routered recess

305

305

455

605

605

755

905

905

  1. Width of cutout

260

260

415

560

560

715

865

865

  1. Overall depth of routered recess

535

535

535

535

535

455

455

535

  1. Depth of cutout

490

490

490

490

490

410

410

490

  1. Corner radius of cutout

max. 10

max. 10

max. 10

max. 10

max. 10

max. 10

max. 10

max. 10

  1. Corner radius of routered recess

max. 2

max. 2

max. 2

max. 2

max. 2

max. 2

max. 2

max. 2

  1. Height of routered recess

5

5

5

5

5

5

5

5

  1. Distance from top of bench to centre of gas inlet on product

35

35

35

35

35

35

35

35

  1. Distance from edge of chassis to gas inlet on product

21

21

21

21

21

21

21

21

  1. Minimum clearance below top of benchtop to: rear top of oven* installed below cooktop or cabinetry thermal protection barrier

75
70

75
70

75
70

75
70

75
70

75
70

75
70

75
70

  1. Router the Benchtop to the specified Depth

2017-07-27_1037.png

  1. Fit the clamping brackets2017-07-27_1038.png

  1. Mask off the area to be siliconed

2017-07-27_1039.png

  1. Apply silicone

2017-07-27_1040.png

Ensure silicone does not leak underneath the glass.

  1. Wipe off excess silicone

2017-07-27_1041.png

  1. If removing product, cut around the silicone

​​​​​​​2017-07-27_1042.png

  • Was this article helpful?