Skip to main content
Fisher & Paykel Product Help

Integrated Models with Badge (GB IE) Only - Installing the Front Panel & Badge Controls

Details how to install the front panel for integrated model with badge only.

Integrated Models with Badge (GB IE) Only - Installing the Front Panel & Badge Controls

1. Determine Badge Cutout Location

WARNING!


 

Electrical Shock Hazard

  • Before continuing, ensure that the product is disconnected from the power supply.
  • Failure to follow this warning may result in electrical shock, injury or fire.

2. Remove Bracket & Disconnect Badge

3. Route Badge Wiring through Panel

4. Attach Panel to Panel Bracket

Use all 14 screws provided as shown.

Align bottom of panel with bottom of bracket

5. Reattach Badge & Earth the Panel

WARNING!


 

Electrical Shock Hazard

  • Connect the integrated badge earth wire to one of the two tabs provided on the panel bracket. To earth the panel bracket, connect electrical shock, injury or fire. the earth wire from the product to the other tab. Any custom metal component (e.g. handle) that extends past the rubber seal must be earthed too.
  • Failure to follow these warnings may result in electrical shock, injury or fire.

6. Attach Panel to Product

When refitting the door pins, ensure they are orientated as shown.

We recommend pushing the drawer runners back 100 mm before attaching the panel. Once the panel is fiited, ensure the runners are fully back into position and the release tabs on both sides are reset fully.

Ensure the rubber seal between the drawer and panel is kept in place.