Skip to main content
Fisher & Paykel Product Help

Gas Connection

 

  • Make sure the connection point will be accessible with the cooktop installed.
  • To enable the gas supply to be readily shut off by the customer, make sure the connection is fitted with an isolating valve close to the cooktop.
  • A manual shut-off valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance.
  • Gas connection to the product must use the nipple supplied with a 1/2” BSP external thread. The supplied gas pressure regulator must be installed where it will be accessible for adjustment.

If Connecting the Gas with a Flexible Hose

  • Ensure the hose is long enough to allow for removal of cooktop for servicing.
  • Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
  • The hose assembly must be with an Rp 1/2” (ISO 7-1) female thread connection.
  • The hose assembly must be as short as practicable and comply with the relevant regulatory requirements.
  • The hose must not be kinked, subjected to abrasion or permanently deformed.
  • The hose must not be near or in contact with any hot surfaces (e.g. base of metal hot plate, flue, or chassis of under counter oven etc.)

 

 

Screen Shot 2018-01-04 at 3.59.49 PM.png
NG LPG
Screen Shot 2018-01-04 at 3.59.54 PM.png Screen Shot 2018-01-04 at 4.00.00 PM.png

Adjust to obtain a test point pressure of 20mbar with
all the burners operating at highest setting.

Make sure the supply pressure is regulated to 29mbar, with all the burners operating at highest setting.

  • Was this article helpful?