Clearance Dimensions

 

Screen Shot 2018-01-05 at 9.59.24 AM.png Screen Shot 2018-01-04 at 3.31.01 PM.png
Front

 

Clearance Dimensions CG301D (mm) CG302D (mm) CG451D (mm) CG603D (mm)
A. Minimum clearance from left edge of cutout to nearest combustible surface 120 120 60 115
B. Minimum clearance from right edge of cutout to nearest combustible surface 120 120 60 115
C. Minimum clearance from rear edge of cutout to:
  • Nearest combustible surface
  • Nearest non-combustible surface

 

85

45

 

160

45

 

85

45

 

160

45

D. Minimum height of non-combustible material when used on adjacent walls 150 150 150 150
E. Minimum clearance from cooktop surface to:
  • Rangehood
  • Any other overhead exhaust fan
  • Downward facing combustible surface
  • Downwards-facing tiled or fire resistant surface

 

650

800

650

500

 

650

800

650

500

 

650

800

650

500

 

650

800

650

500

F. Minimum clearance below top of benchtop to:
  • Combustible surface
  • Fisher & Paykel oven or nearest non-combustible surface

 

70

65

 

70

65

 

70

65

 

70

65

G. Minimum distance from right edge of cooktop to gas connection point on wall (if using a flexible hose) 250

250

250 250
H.  Distance from floor to gas connection point on wall (if using a flexible hose)

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

I.  Maximum overall depth of overhead cabinetry 600 600 600 600
J.  Minimum clearance from the cooktop surface to overhead cabinetry 366 366 366 366
Clearance Dimensions CG604D (mm) CG752D (mm) CG903D (mm) CG905D (mm)
A. Minimum clearance from left edge of cutout to nearest combustible surface 130 115 115 130
B. Minimum clearance from right edge of cutout to nearest combustible surface 115 115 115 115
C. Minimum clearance from rear edge of cutout to:
  • Nearest combustible surface
  • Nearest non-combustible surface

 

160

45

 

125

45

 

125

45

 

160

45

D. Minimum height of non-combustible material when used on adjacent walls 150 150 150 150
E. Minimum clearance from cooktop surface to:
  • Rangehood
  • Any other overhead exhaust fan
  • Downward facing combustible surface
  • Downwards-facing tiled or fire resistant surface

 

650

800

650

500

 

650

800

650

500

 

650

800

650

500

 

650

800

650

500

F. Minimum clearance below top of benchtop to:
  • Combustible surface
  • Fisher & Paykel oven or nearest non-combustible surface

 

70

65

 

70

65

 

70

65

 

70

65

G. Minimum distance from right edge of cooktop to gas connection point on wall (if using a flexible hose) 250 250 250 250
H.  Distance from floor to gas connection point on wall (if using a flexible hose)

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

I.  Maximum overall depth of overhead cabinetry 600 600 600 600
J.  Minimum clearance from the cooktop surface to overhead cabinetry 366 366 366 366
Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of the product, on the right-hand side. It should be accessible with the product installed. 