Cavity Preparation

Important-Icon.png

The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 220-240 VAC min. 9.5 A

2017-08-02_1610-fixed.png

Water Connection

Recommended COLD (Maximum 60°C).
3/4“ BSP (GB20) to suit flat washer.

Water Pressure

Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)

Models without water softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)

Important-Icon.png

Adjacent cabinetry must not extend above cavity base.

 

Integrated models with remote only - Preparation for external venting through same cabinet
2017-08-02_1635-fixed.png 2017-08-03_0930.png

 

Integrated models with remote only - Preparation for external venting through adjacent cabinet
Note-Icon.png

Services can be located either side of dishwasher

The ø60 mm services hole should be enlarged to accommodate the extra venting hose by cutting out some material from the bottom corner

2017-08-03_0924-fixed.jpg

asfdgf.png

Important-Icon.png

To prevent pooling of condensation from the vent hose, a toekick height of no less than 100 mm is required.