Skip to main content
Fisher & Paykel Product Help

Installation Instructions

 

 

Read and follow the ‘Safety and warnings’ and ‘Installation instructions’ sections carefully before using your dryer!

 

Accessories

Please check you received the following accessories with your Fisher & Paykel dryer. You will find them inside the drum:

  • 1 x Installation guide/User guide
  • 1 x Inverted panel
  • 1 x Duct adapter
  • 1 x Wall mounting kit

 

Unpacking

To ensure the best performance from your new dryer please follow the instructions below.

 

Remove All Packaging Before Use

  1. Remove the outer packaging (including the polystyrene packer and plastic wrapping).
  • Ensure packaging materials are kept out of reach of children.
  • Help protect the environment and dispose of the packaging from around the dryer in an environmentally friendly manner.
  1. Tilt the dryer backwards and ‘walk’ it off the base one foot at a time. Not doing so may cause damage to your floor and dryer.
  2. Remove all packaging and accessories from inside the drum and ensure you remove protective covers from the door and console.

 

Location

  • The dryer must be installed in a well-ventilated, dust-free environment.
  • The dryer must not be installed on any textured floor coverings (eg carpet, rugs).
  • Do not install the dryer behind a lockable door, sliding door, or behind a door where the hinge is on the opposite side to that of the dryer in such a way that the full opening of the door is inhibited. Ensure the dryer door can always be opened fully.
  • Do not install the dryer outside, in a damp place, where there is a risk of freezing, where it may be rained on, in direct sunlight or close to a source of heat.
  • Do not place your dryer on top of its power cable.
Install Instruct_Location.PNG

 

Venting

Correct installation is very important for all dryers to ensure maximum efficiency and safety.

Never run the dryer unless the airflow system is free from obstruction.

There must be adequate ventilation to avoid the back flow of gases into the room from appliances burning fuels, including open fires, when operating the dryer.

Exhaust air must not be discharged into a flue which is used for exhausting fumes from appliances burning gas or other fuels.

 

External Venting

Your dryer has been designed to be vented outside to provide the following advantages:

  • Ensures optimum efficiency by preventing recirculation of moist air.
  • Eliminates condensation on walls and ceilings.
  • Reduces the chance of lint being sucked into the dryer.
  • Prevents lint and other fine particles being blown into the room.

 

All External Venting Systems Must Be:

  • Made from 100mm diameter flexible foil sleeved with a galvanised metal pipe where the vent system goes through the wall, or 100mm diameter galvanised metal piping.
  • Exhausted outside and not into another confined space, eg the roof cavity of a house.
  • Fitted with a vent cap outside to stop rain water entering the dryer exhaust system.
  • Angled to avoid condensation running back into the dryer.
  • The vent system should be a maximum of two metres with no more than three 90° bends.
  • Vent systems over two metres long require special installation. Contact a Fisher & Paykel trained and supported service technician.

 

Internal Venting

The dryer is set up in the factory for front venting. If front venting is used there must be adequate ventilation to avoid the build up of moisture in the room, which can affect the performance of the dryer. Venting must comply with local by-laws and regulations.

 

Installation Options

There are two different ways your dryer can be positioned. Freestanding or inverted and mounted on a wall. Freestanding The dryer stands on the floor and can easily be moved into position.

Freestanding

The dryer stands on the floor and can easily be moved into position.

  1. Move the dryer into the desired position. Do not lift the dryer by the top panel.
  2. Have a minimum clearance on all sides of at least 20mm.
  3. Have a minimum clearance at the rear of 75mm. The spacers from the accessory wall mounting kit can be used to set this distance.
  4. Install the dryer on a stable and level floor.

 

Freestanding Venting Options

The vent system should be less than two metres long with no more than three 90⁰ bends. 

Before a rear venting option is installed the dryer must be changed from the front venting factory setup. Remove the outlet grille from the front left-hand side and replace with the outlet cover from the rear left-hand side. These covers should be gently pried at the sides to prevent damage.

 

External Venting

The dryer is vented with a kit that can be positioned to remove air to the side.

The dryer is vented directly through the wall using a ducting kit in combination with the duct adaptor supplied with the dryer.

The dryer is vented through a window using a ducting kit in combination with the duct adaptor supplied with the dryer. This requires the dryer to be a minimum distance of 140mm from the wall to ensure the ducting is not restricted with tight bends or can be crushed.

 

Internal Venting

Front venting is the only recommended option for venting into the room. The dryer is set up for front venting when it leaves the factory.

Where possible all efforts should be made to vent the dryer externally to avoid moisture build up around the dryer.

Install Instruct_External Venting with Part PD_DK4W.PNG

External venting with kit part number PD-DK4W

Install Instruct_External Venting with Part PD_SVHCW4.PNG

External venting with kit part number PD-SVHCW4

Install Instruct_External Venting with Part PD_F0408.PNG

External venting with kit part number PD-F0408

 

Inverted Wall Mounting Installation

Your dryer has been designed to be inverted and mounted on the wall above a washer or tub. A wall mounting kit must be used. Inverting allows access to the dryer control panel.

Tools and parts required:

  • Drill and 3mm bit
  • Cross-head screwdriver.

Wall mounting kit includes:

  • 2 x Plastic spacers
  • 2 x Wall hanging brackets
  • 2 x Hanging hook
  • 4 x Wood screws
  • 6 x Screws for hanging hooks and plastic spacers.

 

Inverted Wall Mounting

 

Install Instruct_Inverted Wall Mounting.PNG

 

Wall Mounting

  1. Determine the position of the dryer on the wall and mark the bracket position. A minimum of 50mm is needed between the top of the dryer and the ceiling for ease of installation. If mounting above a washing machine, allow sufficient room to open the lid of the washer. Refer to 'Inverted Wall Mounting' for lid clearances.
  2. Fix the wall hanging brackets to the wall securely, ie into the stud. If the studs are too far apart, fit a timber slat to the studs and then mount the brackets to the slat. If a slat is used, install a second slat behind the spacers to ensure the dryer is horizontal. The distance between the centre of each bracket is 555mm (A).
  3. To install the hooks onto the dryer, remove one screw from each side (B), reuse these screws with two more (each side) from the kit to fasten the hooks in place.
  4. Remove plastic plugs from the back of the dryer and screw the spacers provided in place (C).
  5. With assistance, mount the dryer on the wall brackets.
  6. Fit inverted control panel over the existing panel.
  7. Adjust the display to read correctly on an inverted panel:
    • For DE7060M, DE6060M and DE5060M press Single_PadLock.JPG and Clothes Symbol.PNG for three seconds.
    • For DE4560M press Single_PadLock.JPG and Air Dry Symbol..PNG for three seconds.
    • The dryer will beep to indicate you have made a correct selection, and the display will change after three seconds.
    • Repeat the same steps to return the panel to the factory setting.

Install Instruct_Mounting Dryer on Wall.PNG

 

Before a rear venting option is installed the dryer must be changed from the front venting factory setup. Remove the outlet grille from the front left-hand side and replace with the outlet cover from the rear left-hand side. These covers should be gently pried at the sides to prevent damage.

 

External Venting Options

  • Kits are available that allow the dryer to be vented upwards or to the side.
  • The dryer can be vented directly through the wall with a kit, in combination with the duct adaptor supplied with the dryer.
The vent system should be less than two metres long with no more than three 90⁰ bends.

 

Internal Venting

Front venting is the only option for internal venting. The dryer is set up for front venting when it leaves the factory.

Where possible all efforts should be made to vent the dryer externally to avoid moisture build up around the dryer.

 

Electrical Connection

  1. This appliance must be connected to a 220V – 240V, 50Hz, sinusoidal, 10A electrical supply.
  2. Uncoil the power cord, remove and discard the plastic pin cover and plug into a power socket.
  3. Connect the appliance to an earthed outlet protected by a fuse of suitable capacity.
  • Check the power cord for damage and make sure it is not squashed or twisted when installing the dryer.
  • Always remove the power cord from the power socket by the plug, not by the cord.

Install Instruct_External Venting Options with Part PD_DK4W.PNG

External venting with kit part number PD-DK4W

Install Instruct_External Venting Options with Part PD_SVHCW4.PNG

External venting with kit part number PD-SVHCW4

 

  • Do not touch or operate the dryer with wet hands or with bare feet.
  • A damaged power cord must be replaced by a Fisher & Paykel trained and supported service technician. The appliance must not be operated until it is repaired, as there is risk of electric shock.
  • Do not operate this dryer if it has been damaged during transport. Contact your Fisher & Paykel dealer or Fisher & Paykel trained and supported service technician.
The appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by a utility.

 

Completing the Installation

Installation Test Cycle

Ensure the installation test cycle is completed before you dry any items in your dryer. This checks your dryer is installed correctly and functioning properly prior to use.
  1. Turn your dryer on by pressing ‘POWER’ Start Button.JPG.
  2. Select the ‘Time Dry’ cycle for 30 minutes. Ensure the drum is empty and the door is closed (you will hear it click shut).
  3. Press Start_Pause Button.JPG, the drum will start rotating.
    • Observe the dryer for any problems.
    • The dryer will beep and display any faults on the screen if there are any problems. Refer to ‘Fault codes’.
  4. At the completion of the cycle open the door and check that there is warmth inside the dryer. This indicates the dryer is operating normally
If there are any problems, you must address these before proceeding with normal use. The dryer will automatically turn off at the end of the cycle if there are no problems.

Before you start, it is a good idea to go through the following checklist:

  1. Has the packaging been removed?
  2. Is the lint filter correctly in place?
  3. Has the power cord been connected to an appropriate power supply and the power turned on?
  4. Have you performed the installation test cycle?

 

Product Specifications

  DE4560M

DE5060M

DE5060MU

DE6060M DE7060M
Capacity (kg)* 4.5 5 6 7
Dimensions (mm)        
Width 600 600 600 600
Depth 481 571 571 571
Height 825 825 825 825
Electrical        
Volts 220 – 240 220 – 240 220 – 240 220 – 240
Hz 50 50 50 50
Amps (maximum) 10 10 10 10
Rated Power (W) 1750 1750 1750 1770

* Capacity refers to the maximum dry weight of items the dryer can dry at any one time.

Rated capacity is determined by a countries performance standards, so similar dryers may have different capacities for different markets.

 

 

 

  • Was this article helpful?